{"id":1801,"date":"2026-07-08T07:28:03","date_gmt":"2026-07-08T07:28:03","guid":{"rendered":"https:\/\/innokie.com\/?post_type=product&#038;p=1801"},"modified":"2026-07-08T07:28:03","modified_gmt":"2026-07-08T07:28:03","slug":"sau1520-online-trace-oxygen-analyzer","status":"publish","type":"product","link":"https:\/\/innokie.com\/de\/produkt\/sau1520-online-trace-oxygen-analyzer\/","title":{"rendered":"SAU1520 Online Trace Oxygen Analyzer"},"content":{"rendered":"<h3 data-section-id=\"miz626\" data-start=\"0\" data-end=\"24\"><span role=\"text\"><strong data-start=\"4\" data-end=\"24\">Product Overview<\/strong><\/span><\/h3>\n<p data-start=\"26\" data-end=\"439\" data-is-last-node=\"\" data-is-only-node=\"\">The SAU1520 Online Trace-Oxygen Analyzer is a new online trace-oxygen analyzer launched by INNOKIE Technology GmbH. It uses an advanced electrochemical sensor and digital electronic technology. It has high sensitivity and low power consumption. It is designed to provide reliable and accurate oxygen measurement. It is suitable for fixed-point and real-time oxygen content measurement in various industrial sites.<\/p>\n<h3 data-section-id=\"1w4ir3e\" data-start=\"0\" data-end=\"24\"><span role=\"text\"><strong data-start=\"4\" data-end=\"24\">Produkteigenschaften<\/strong><\/span><\/h3>\n<ul data-start=\"26\" data-end=\"379\" data-is-last-node=\"\" data-is-only-node=\"\">\n<li data-section-id=\"r6up87\" data-start=\"26\" data-end=\"47\">3.5-inch HD display<\/li>\n<li data-section-id=\"gj461t\" data-start=\"48\" data-end=\"92\">Integrated sampling chamber, fast response<\/li>\n<li data-section-id=\"uhzpu2\" data-start=\"93\" data-end=\"129\">Long sensor life and high accuracy<\/li>\n<li data-section-id=\"1ow1tef\" data-start=\"130\" data-end=\"170\">High compatibility and easy to install<\/li>\n<li data-section-id=\"x33hm4\" data-start=\"171\" data-end=\"224\">Multi-parameter display: ppm \/ average \/ trend line<\/li>\n<li data-section-id=\"mwg73z\" data-start=\"225\" data-end=\"309\">AC or DC power supply options are available, suitable for various industrial sites<\/li>\n<li data-section-id=\"1xk1f1y\" data-start=\"310\" data-end=\"379\" data-is-last-node=\"\">Innovative four-way valve for quick shut-off and sensor replacement<\/li>\n<\/ul>\n<h3 data-section-id=\"mfhxx1\" data-start=\"0\" data-end=\"29\"><span role=\"text\"><strong data-start=\"4\" data-end=\"29\">Branchenanwendungen<\/strong><\/span><\/h3>\n<ul data-start=\"31\" data-end=\"512\" data-is-last-node=\"\" data-is-only-node=\"\">\n<li data-section-id=\"n689w8\" data-start=\"31\" data-end=\"58\">Petrochemie, Chemie<\/li>\n<li data-section-id=\"m5donf\" data-start=\"59\" data-end=\"78\">Stahl, Metallurgie<\/li>\n<li data-section-id=\"mc2m4p\" data-start=\"79\" data-end=\"101\">Kraft-W\u00e4rme-Kopplung, Kokerei<\/li>\n<li data-section-id=\"z6kpea\" data-start=\"102\" data-end=\"129\">PVC, Polysilizium, Ammoniak<\/li>\n<li data-section-id=\"uispy2\" data-start=\"130\" data-end=\"238\">O\u2082 aus Luftzerlegung, N\u2082 aus Luftzerlegung, automatische Analyse des Sauerstoffgehalts in chemischen Prozessen<\/li>\n<li data-section-id=\"6fsr8x\" data-start=\"239\" data-end=\"352\">Analysis of oxygen content in protective gases for the electronics industry (trace oxygen analysis in Nitrogen)<\/li>\n<li data-section-id=\"1w1om5b\" data-start=\"353\" data-end=\"438\">Analyse des Sauerstoffgehalts in Schutzgasen in Hochtemperatursinter\u00f6fen<\/li>\n<li data-section-id=\"1so35f\" data-start=\"439\" data-end=\"512\" data-is-last-node=\"\">Analyse des Sauerstoffgehalts in der Glas- und Baustoffindustrie<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"gqkziz\" data-start=\"0\" data-end=\"32\"><span role=\"text\"><strong data-start=\"4\" data-end=\"32\">Technische Spezifikationen<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"143\" data-end=\"1049\">\n<thead data-start=\"143\" data-end=\"167\">\n<tr data-start=\"143\" data-end=\"167\">\n<th class=\"last:pe-10\" data-start=\"143\" data-end=\"150\" data-col-size=\"sm\">Artikel<\/th>\n<th class=\"last:pe-10\" data-start=\"150\" data-end=\"167\" data-col-size=\"lg\">Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"178\" data-end=\"1049\">\n<tr data-start=\"178\" data-end=\"221\">\n<td data-start=\"178\" data-end=\"202\" data-col-size=\"sm\">Messprinzip<\/td>\n<td data-col-size=\"lg\" data-start=\"202\" data-end=\"221\">Elektrochemisch<\/td>\n<\/tr>\n<tr data-start=\"222\" data-end=\"279\">\n<td data-start=\"222\" data-end=\"230\" data-col-size=\"sm\">Messbereich<\/td>\n<td data-col-size=\"lg\" data-start=\"230\" data-end=\"279\">(0~1\/10\/100\/1000) ppm, 0~1% (Automatic range)<\/td>\n<\/tr>\n<tr data-start=\"280\" data-end=\"303\">\n<td data-start=\"280\" data-end=\"291\" data-col-size=\"sm\">Genauigkeit<\/td>\n<td data-start=\"291\" data-end=\"303\" data-col-size=\"lg\">&lt;1% F.S.<\/td>\n<\/tr>\n<tr data-start=\"304\" data-end=\"329\">\n<td data-start=\"304\" data-end=\"317\" data-col-size=\"sm\">Aufl\u00f6sung<\/td>\n<td data-start=\"317\" data-end=\"329\" data-col-size=\"lg\">0.01 ppm<\/td>\n<\/tr>\n<tr data-start=\"330\" data-end=\"358\">\n<td data-start=\"330\" data-end=\"346\" data-col-size=\"sm\">Wiederholbarkeit<\/td>\n<td data-col-size=\"lg\" data-start=\"346\" data-end=\"358\">&lt;1% F.S.<\/td>\n<\/tr>\n<tr data-start=\"359\" data-end=\"388\">\n<td data-start=\"359\" data-end=\"375\" data-col-size=\"sm\">Ansprechzeit<\/td>\n<td data-start=\"375\" data-end=\"388\" data-col-size=\"lg\">T90 \u2264 15s<\/td>\n<\/tr>\n<tr data-start=\"389\" data-end=\"420\">\n<td data-start=\"389\" data-end=\"406\" data-col-size=\"sm\">Measuring Flow<\/td>\n<td data-col-size=\"lg\" data-start=\"406\" data-end=\"420\">(1~2) SCFH<\/td>\n<\/tr>\n<tr data-start=\"421\" data-end=\"457\">\n<td data-start=\"421\" data-end=\"442\" data-col-size=\"sm\">Operation Pressure<\/td>\n<td data-col-size=\"lg\" data-start=\"442\" data-end=\"457\">(0~0.1) MPa<\/td>\n<\/tr>\n<tr data-start=\"458\" data-end=\"493\">\n<td data-start=\"458\" data-end=\"482\" data-col-size=\"sm\">Operation Temperature<\/td>\n<td data-col-size=\"lg\" data-start=\"482\" data-end=\"493\">(5~45)\u2103<\/td>\n<\/tr>\n<tr data-start=\"494\" data-end=\"524\">\n<td data-start=\"494\" data-end=\"504\" data-col-size=\"sm\">Anzeige<\/td>\n<td data-start=\"504\" data-end=\"524\" data-col-size=\"lg\">3.5&#8243; LCD display<\/td>\n<\/tr>\n<tr data-start=\"525\" data-end=\"625\">\n<td data-start=\"525\" data-end=\"540\" data-col-size=\"sm\">Datenspeicherung<\/td>\n<td data-col-size=\"lg\" data-start=\"540\" data-end=\"625\">Built-in data storage; can be exported in PDF or Excel format via a host computer<\/td>\n<\/tr>\n<tr data-start=\"626\" data-end=\"659\">\n<td data-start=\"626\" data-end=\"634\" data-col-size=\"sm\">Power<\/td>\n<td data-start=\"634\" data-end=\"659\" data-col-size=\"lg\">110~220V\/AC or 24V\/DC<\/td>\n<\/tr>\n<tr data-start=\"660\" data-end=\"799\">\n<td data-start=\"660\" data-end=\"683\" data-col-size=\"sm\">Communication Method<\/td>\n<td data-col-size=\"lg\" data-start=\"683\" data-end=\"799\">Analog outputs: 4\u201320 mA, 0\u201320 mA, 0\u201324 mA; 0\u20135 V, 0\u201310 V; RS-485 with standard Modbus-RTU communication protocol<\/td>\n<\/tr>\n<tr data-start=\"800\" data-end=\"871\">\n<td data-start=\"800\" data-end=\"821\" data-col-size=\"sm\">Gas Path Interface<\/td>\n<td data-col-size=\"lg\" data-start=\"821\" data-end=\"871\">1\/4&#8243; or 1\/8&#8243; stainless steel ferrule connector<\/td>\n<\/tr>\n<tr data-start=\"872\" data-end=\"918\">\n<td data-start=\"872\" data-end=\"892\" data-col-size=\"sm\">Overall Dimension<\/td>\n<td data-col-size=\"lg\" data-start=\"892\" data-end=\"918\">(185W \u00d7 238H \u00d7 96D) mm<\/td>\n<\/tr>\n<tr data-start=\"919\" data-end=\"969\">\n<td data-start=\"919\" data-end=\"928\" data-col-size=\"sm\">Gewicht<\/td>\n<td data-col-size=\"lg\" data-start=\"928\" data-end=\"969\">About 2.5 kg (standard configuration)<\/td>\n<\/tr>\n<tr data-start=\"970\" data-end=\"1049\">\n<td data-start=\"970\" data-end=\"996\" data-col-size=\"sm\">Optionale Konfigurationen<\/td>\n<td data-col-size=\"lg\" data-start=\"996\" data-end=\"1049\">Quick-connect fittings, filter, PC software, etc.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>","protected":false},"featured_media":1802,"comment_status":"open","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":""},"product_brand":[],"product_cat":[23],"product_tag":[],"class_list":{"0":"post-1801","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-oxygen-analyzers","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"uagb_featured_image_src":{"full":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/SAU1520.jpg",1000,1000,false],"thumbnail":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/SAU1520-150x150.jpg",150,150,true],"medium":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/SAU1520-300x300.jpg",300,300,true],"medium_large":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/SAU1520-768x768.jpg",768,768,true],"large":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/SAU1520.jpg",1000,1000,false],"1536x1536":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/SAU1520.jpg",1000,1000,false],"2048x2048":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/SAU1520.jpg",1000,1000,false],"trp-custom-language-flag":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/SAU1520-12x12.jpg",12,12,true],"woocommerce_thumbnail":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/SAU1520-300x300.jpg",300,300,true],"woocommerce_single":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/SAU1520-600x600.jpg",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/SAU1520-100x100.jpg",100,100,true]},"uagb_author_info":{"display_name":"icestantongljohntrembl@gmail.com","author_link":"https:\/\/innokie.com\/de\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"Technical Specifications Item Specification Measurement Principle Electrochemical Range (0~1\/10\/100\/1000) ppm, 0~1% (Automatic range) Accuracy &lt;1% F.S. Resolution 0.01 ppm Repeatability &lt;1% F.S. Response Time T90 \u2264 15s Measuring Flow (1~2) SCFH Operation Pressure (0~0.1) MPa Operation Temperature (5~45)\u2103 Display 3.5\" LCD display Data Storage Built-in data storage; can be exported in PDF or Excel format&hellip;","_links":{"self":[{"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/product\/1801","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/comments?post=1801"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/media\/1802"}],"wp:attachment":[{"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/media?parent=1801"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/product_brand?post=1801"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/product_cat?post=1801"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/product_tag?post=1801"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}