{"id":1807,"date":"2026-07-08T07:43:51","date_gmt":"2026-07-08T07:43:51","guid":{"rendered":"https:\/\/innokie.com\/?post_type=product&#038;p=1807"},"modified":"2026-07-08T07:43:51","modified_gmt":"2026-07-08T07:43:51","slug":"sau8050-rack-mounted-oxygen-analyzer","status":"publish","type":"product","link":"https:\/\/innokie.com\/de\/produkt\/sau8050-rack-mounted-oxygen-analyzer\/","title":{"rendered":"SAU8050 Rack-Mounted Oxygen Analyzer"},"content":{"rendered":"<h3>Working Principle<\/h3>\n<p>The SAU8050 Coulometric Oxygen Analyzer adopts the coulometric method for oxygen measurement, a widely used high-precision detection technique. When the sample gas enters the sensor, redox reactions occur and trigger electron migration. The electrons are conducted out via electrodes, and the oxygen content can be accurately calculated by measuring the electric charge generated between the two sensor electrodes.<\/p>\n<p>The specially designed cathode material of the sensor can capture and react with ultra-trace oxygen molecules, enabling the analyzer to deliver much higher measurement accuracy than similar products. After cutting off the gas supply, the cathode can completely consume residual oxygen inside the sensor. Equipped with an inherent zero reference, this analyzer can perform zero calibration for itself and other oxygen measuring devices.<\/p>\n<p><strong>Alkaline Sensor Reaction:<\/strong><\/p>\n<p>Cathode: O\u2082 + 2H\u2082O + 4e\u207b \u2192 4OH\u207b<\/p>\n<p>Anode: 2Pb + 4OH\u207b \u2192 2PbO + 2H\u2082O + 4e\u207b<\/p>\n<p><strong>Complete Chemical Reaction:<\/strong><\/p>\n<p>O\u2082 + 2Pb \u2192 2PbO<\/p>\n<h3>Anwendungsbereiche<\/h3>\n<p>The SAU8050 Coulometric Oxygen Analyzer is a new high-precision multi-functional unit for ppm\/ppb-level oxygen detection.<\/p>\n<p>Suitable for industrial and laboratory gas analysis, it accurately measures oxygen at critical production process points. It also calibrates other trace oxygen analyzers, particularly for batch verification of bottled standard oxygen gas.<\/p>\n<p>Widely adopted in petrochemical, industrial gas, semiconductor, biopharmaceutical, and food industries for oxygen content testing.<\/p>\n<h3>Main Features<\/h3>\n<h4>Precise &amp; Efficient<\/h4>\n<ul>\n<li>Highly integrated gas circuit with bypass fast contamination replacement, enabling fast and efficient testing.<\/li>\n<li>Constant pressure and flow steady-state control, anti-interference against sample gas fluctuation, ensuring stable and reliable operation.<\/li>\n<li>Special full-reaction electrolyte, intelligent T-P dual compensation, and full-span accurate calibration for flawless readings.<\/li>\n<\/ul>\n<h4>Safe &amp; Durable<\/h4>\n<ul>\n<li>Built-in pressure protection avoids sensor damage caused by overpressure or negative pressure.<\/li>\n<li>Integrated seal design reduces contamination and electrolyte volatilization, extending sensor life.<\/li>\n<li>Maintenance-free sensor with external fast refilling.<\/li>\n<\/ul>\n<h4>Intelligent Operation<\/h4>\n<ul>\n<li>5-inch intelligent color touchscreen with graphic guidance, supporting operation in Chinese, English, and German.<\/li>\n<li>Intelligent multi-display functions: multi-parameter and multi-window presentation, trend curves, maximum\/minimum values, difference values, average values, and more.<\/li>\n<\/ul>\n<h4>Wide Application<\/h4>\n<ul>\n<li>Strict EMC design adapts to complex industrial and commercial scenarios.<\/li>\n<li>Diverse gas circuit interfaces and communication modes fit a broad range of working conditions.<\/li>\n<\/ul>\n<h4>Elegant Appearance<\/h4>\n<ul>\n<li>Premium 19-inch standard chassis with refined look for easy system integration.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<h3>Technische Parameter<\/h3>\n<h4>Analyseparameter<\/h4>\n<table>\n<tbody>\n<tr>\n<td>Messprinzip<\/td>\n<td>Coulometric method<\/td>\n<\/tr>\n<tr>\n<td>Elektrode<\/td>\n<td>Lead &amp; Silver<\/td>\n<\/tr>\n<tr>\n<td>Messbereich<\/td>\n<td>(0~10\/100) ppm (auto-ranging)<\/td>\n<\/tr>\n<tr>\n<td>Aufl\u00f6sung<\/td>\n<td>1 ppb<\/td>\n<\/tr>\n<tr>\n<td>Genauigkeit<\/td>\n<td>&lt; 1% F.S.<\/td>\n<\/tr>\n<tr>\n<td>Ansprechzeit<\/td>\n<td>T90 \u2264 30s<\/td>\n<\/tr>\n<tr>\n<td>Lower Detection Limit<\/td>\n<td>2 ppb<\/td>\n<\/tr>\n<tr>\n<td>Gas Circuit Connector<\/td>\n<td>1\/8&#8243; or 1\/4&#8243; stainless steel ferrule fittings; 1\/4&#8243; VCR fittings (optional)<\/td>\n<\/tr>\n<tr>\n<td>Gas Path System<\/td>\n<td>The gas circuit is equipped with protection and control system, which is immune to fluctuations in sample gas pressure.<\/td>\n<\/tr>\n<tr>\n<td>Proben\u00adgasdruck<\/td>\n<td>(0~15) MPa<\/td>\n<\/tr>\n<tr>\n<td>Betriebsdruck<\/td>\n<td>(0~0.05) MPa<\/td>\n<\/tr>\n<tr>\n<td>Measuring Flow Rate<\/td>\n<td>100 mL\/min<\/td>\n<\/tr>\n<tr>\n<td>Bypass-Durchfluss<\/td>\n<td>(500~800) mL\/min<\/td>\n<\/tr>\n<tr>\n<td>Abmessungen<\/td>\n<td>19-inch 4U standard chassis (468L \u00d7 382W \u00d7 177H) mm<\/td>\n<\/tr>\n<tr>\n<td>Operating Environment<\/td>\n<td>(5~45)\u00b0C, Humidity: &lt; 85%RH<\/td>\n<\/tr>\n<tr>\n<td>Storage Environment<\/td>\n<td>(5~45)\u00b0C, Humidity: &lt; 85%RH<\/td>\n<\/tr>\n<tr>\n<td>Power<\/td>\n<td>(100~240) VAC 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Communication Modes<\/td>\n<td>Analog output: 4~20 mA, 0~20 mA, 0~5 V, 0~10 V; RS485 with Modbus-RTU protocol (optional)<\/td>\n<\/tr>\n<tr>\n<td>Datenspeicherung<\/td>\n<td>Onboard data storage with capacity for over 5 million records (optional)<\/td>\n<\/tr>\n<tr>\n<td>Softwareunterst\u00fctzung<\/td>\n<td>PC software enabling data export and logging via Type-C; supports Excel and PDF export (optional)<\/td>\n<\/tr>\n<tr>\n<td>Algorithm Compensation<\/td>\n<td>Built-in temperature and pressure compensation to eliminate measurement inaccuracies induced by ambient temperature fluctuations<\/td>\n<\/tr>\n<tr>\n<td>Alarm Output<\/td>\n<td>With high and low alarm outputs<\/td>\n<\/tr>\n<tr>\n<td>Display Screen<\/td>\n<td>5-inch high-definition color touchscreen<\/td>\n<\/tr>\n<tr>\n<td>Available Languages<\/td>\n<td>Deutsch, Englisch, Chinesisch<\/td>\n<\/tr>\n<tr>\n<td>Anzeige-Modus<\/td>\n<td>Parameter readout, multi-window display with trend curves<\/td>\n<\/tr>\n<tr>\n<td>Available Units<\/td>\n<td>ppm\/ppb<\/td>\n<\/tr>\n<tr>\n<td>Steuerungsmodus<\/td>\n<td>Graphic-guided touch operation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":1808,"comment_status":"open","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":""},"product_brand":[],"product_cat":[23],"product_tag":[],"class_list":{"0":"post-1807","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-oxygen-analyzers","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"uagb_featured_image_src":{"full":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/sau8050.jpg",1000,1000,false],"thumbnail":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/sau8050-150x150.jpg",150,150,true],"medium":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/sau8050-300x300.jpg",300,300,true],"medium_large":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/sau8050-768x768.jpg",768,768,true],"large":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/sau8050.jpg",1000,1000,false],"1536x1536":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/sau8050.jpg",1000,1000,false],"2048x2048":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/sau8050.jpg",1000,1000,false],"trp-custom-language-flag":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/sau8050-12x12.jpg",12,12,true],"woocommerce_thumbnail":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/sau8050-300x300.jpg",300,300,true],"woocommerce_single":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/sau8050-600x600.jpg",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/innokie.com\/wp-content\/uploads\/2026\/07\/sau8050-100x100.jpg",100,100,true]},"uagb_author_info":{"display_name":"icestantongljohntrembl@gmail.com","author_link":"https:\/\/innokie.com\/de\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"Technical Parameters Analyzer Parameters Measurement Principle Coulometric method Electrode Lead &amp; Silver Measuring Range (0~10\/100) ppm (auto-ranging) Resolution 1 ppb Accuracy &lt; 1% F.S. Response Time T90 \u2264 30s Lower Detection Limit 2 ppb Gas Circuit Connector 1\/8\" or 1\/4\" stainless steel ferrule fittings; 1\/4\" VCR fittings (optional) Gas Path System The gas circuit is&hellip;","_links":{"self":[{"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/product\/1807","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/comments?post=1807"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/media\/1808"}],"wp:attachment":[{"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/media?parent=1807"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/product_brand?post=1807"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/product_cat?post=1807"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/innokie.com\/de\/wp-json\/wp\/v2\/product_tag?post=1807"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}